CRi CRi

Skip to content

Multimedia

Maestro

Movie of DyCE time series (gif)
Time sequence of Dynamic Contract Enhancement (DyCE) acquisition. The final DyCE image shows each organ in pseudocolor (heart = red, gut = blue, lungs = yellow, liver = cyan, brain = white, etc).
Courtesy Elizabeth Hillman, Columbia University, New York, NY

Maestro software: RCA demonstration (avi)
Qdot, food, and autofluorescence signals are separated from each other using the Real Component Analysis (RCA) tool in CRi's Maestro software.
Sample courtesy Shuming Nie, Emory University, Atlanta, GA

DyCE demonstration (avi)
Movie demonstrating the new Dynamic Contrast Enhancement (DyCE) tool available in CRi's Maestro software. The MultiView platform is shown, along with display options, and a comparison to a CT mouse atlas image.
Sample courtesy Elizabeth Hillman, Columbia University, New York, NY

Maestro software: how to unmix a spectral cube (gif)
FITC, Cy3.5, TRITC, and autofluorescence signals are cleanly separated and then displayed in a Maestro unmixed image.
Sample and images courtesy of R. Weissleder, U. Mahmood and J. Tam, MGH, Boston, MA

Maestro spectral image series of unmixed data (gif)
Spectral imaging enables multiplexing, even in the near-infrared. Here we see four signals, AF680 (green). AF700 (blue), AF750 (red), and Matrigel (gray), along with combinations of two (cyan) and three (pink) markers.
Sample courtesy Stanford University Workshop


Nuance

Nuance software: how to unmix a spectral cube (avi)
Movie showing the Nuance spectral unmixing tools available for chromogenic microscopy, in this case separating spectrally and spatially overlapping hematoxylin and DAB signals.

Nuance software: RCA demonstration (avi)
Movie of the Nuance Real Component Analysis (RCA) spectral unmixing tool available for fluorescence microscopy, in this case separating two qdot signals from autofluorescence.

Nuance Chromogenic spectral image series of unmixed data (gif)
Multiple signals, including hematoxylin, ki67, pHH3, and CC3, unmixed using CRi's Nuance system. Note the options available for displaying different combinations of signals in pseudocolor.
Images courtesy Chris Kerfoot, Mosaic Labs

Nuance Fluorescence spectral image series of unmixed data (gif)
Six signals (DAPI + Ki67 + CD3 + CD20 + IgD + CD68) separated and displayed independently and in unmixed Nuance pseudocolor.
Sample courtesy Stephania Pittaluga, NCI


Oosight

Movie of Enucleation of Rhesus Monkey Oocyte (avi)
Screencapture of Oosight system being used for enucleation of rhesus monkey oocytes. Note the high-contrast Live Oosight mode, versus conventional imaging.
Sample courtesy Shoukhrat Mitalipov, Oregon National Primate Research Center, OHSU


Abrio

Movie of a living growth cone (avi)
Time-lapse retardance magnitude movie of the architectural dynamics of fine structure in the growth cone cytoskeleton of an Aplysia bag cell neuron.
Courtesy Kaoru Katoh, Katherine Hammer, Peter J.S. Smith, Rudolf Oldenbourg; MBL, Woods Hole, MA

Moving of a crane fly spermatocyte undergoing Meiosis (avi)
Time-lapse retardance magnitude movie showing meiosis I of the spermatocyte of the crane fly (Nephrotoma suturalis).
Courtesy James LaFountain, University at Buffalo, Buffalo, NY and Rudolf Oldenbourg, MBL, Woods Hole, MA